Skydioenterprise2100g Takeoff Weight

Skydio X10: Limiti di Vento & Specifiche Meteo

Prestazioni aerodinamiche, tolleranza al vento e limiti operativi a basse temperature per il Skydio X10 di Skydio.

Skydio X10 aerial drone in flightPlaceholder — needs official product photo
Risposta Rapida & Sintesi Meteo

The Skydio X10 enterprise drone features IP54 rainproof weather sealing, 12.8 m/s (46.0 km/h / 28.6 mph / Beaufort 6) wind resistance, and an operating temperature range of -20°C to 45°C. It integrates night vision and radiometric thermal.

Controllo Fattibilità in Tempo Reale per Skydio X10

Idoneo al Volo (Entro i Limiti)

New York (40.71°, -74.01°)

Visualizza Finestra a 7 Giorni

Matrice Tecnica dei Limiti di Volo

Resistenza Massima al Vento
12.8 m/s
12.8 m/s • 46 km/h • 28.6 mph • Beaufort 6
Temperatura Operativa
-20°C to 45°C
-20°C to 45°C (-4°F to 113°F)
Pioggia & Protezione IP
IP54 Rainproof
Protezione Certificata contro la Pioggia
Quota Massima di Servizio
5,000 m
16,404 ft ASL
Batteria & Autonomia
8400 mAh
Li-ion (21.6V)35 min max
Peso al Decollo e Classe
2100 grams
Enterprise / Pesante

Aerodinamica & Risposta al Vento del Skydio X10

The Skydio X10 is an enterprise autonomous drone featuring an IP54 weather-sealed airframe, NVIDIA Jetson Orin processing, and modular high-resolution optical and FLIR Boson+ radiometric thermal sensors. It executes autonomous inspection and emergency response in rain, snow, and night conditions.

Volo Invernale & Comportamento Chimico della Batteria

Self-heating smart batteries operate down to -20°C (-4°F). Night autonomous vision navigation uses active illumination to bypass low-light limits.

Vento Forte & Wind Shear Verticale

With 12.8 m/s wind resistance and heavy 2.1kg frame, the X10 maintains stable position during stormy industrial inspections.

Domande Frequenti sul Skydio X10

Risposte autorevoli a domande frequenti su vento, pioggia, basse temperature e limiti di volo.

Yes. The Skydio X10 is IP54 certified for flight in rain, snow, dust, and moisture.

The maximum wind resistance is 12.8 m/s (46 km/h / 28.6 mph / Beaufort 6).

-20°C to 45°C (-4°F to 113°F).

Yes, the X10 incorporates visible and infrared active illuminators along with high-sensitivity navigation sensors for zero-light obstacle avoidance.

A radiometric FLIR Boson+ 640x512 thermal sensor with industry-leading ≤30 mK thermal sensitivity.

Strumenti Meteo per Piloti di Skydio X10

Specifiche ricavate dalla documentazione tecnica ufficiale di Skydio per il Skydio X10.